THEORETICAL ANALYSIS OF A WET COOLING TOWER FOR FRESH WATER FROM PLUME AND ANALYZING AN INDUSTRIAL COOLING TOWER BASED ON RESULTS

Journal Title: JOURNAL OF ADVANCES IN CHEMISTRY - Year 2017, Vol 13, Issue 10

Abstract

A cooling tower is a heat rejection device which rejects waste heat to the atmosphere through the cooling of a water stream to a lower temperature. The stream of saturated exhaust air leaving the cooling tower called the plume is visible when water vapor it contains condenses in contact with cooler ambient air, like the saturated air in one's breath fogs on a cold day. Under certain conditions, the cooling tower plume may present fogging or icing hazards to its surroundings and gives some environmental problems. To find the solution for this problem a cooling tower has been analysed based on air flow rate through the tower and the cooling load to obtain fresh water yield by utilising plume from cooling tower top. The theoretical analysis gives the values of important parameters Theoretical analysis has been done on wet cooling tower by varying the water flow rate through which affect the performance of a cooling tower such as the cooling range, effectiveness, approach, fresh water yield etc. Then with the conditions of a trials from the analysis, the mass flow rate of water in the cooling tower was scaled up to match the mass flow rate of water in an industrial cooling tower. This helps in obtaining the mass flow rate of the air and fresh water yield through the industrial cooling tower.

Authors and Affiliations

Sella Muthu, C Manoharan, R Senthilkumar

Keywords

Related Articles

Weight Loss Corrosion Study of Some Metals in Acid Medium

This research was undertaken to examine the corrosion behavior of some metals in different acid solutions using weight loss technique. The magnitude of corrosion of these metals in 0.5 – 3.0 M of solutions of HCl, H2SO...

EXTRACTION OF CRUDE ESSENTIAL FROM SENNA ALATA (POKOK GELENGGANG)

Senna alata was one of the herbs plants that can be used to treat the ringworm in traditional method. In this study, the senna alata was scientifically tested to prove the traditional medicinal used. Six forms of extract...

Synthesis and thermodynamics of the reactions of [Pd(Eten)(H2O)2]2+ with ligands of biological significane with reference to the antitumour activity

Pd(Eten)Cl2  complex, where Eten = N-ethylethylenediamine , was synthesized and characterized by elemental analysis and spectroscopic techniques. The stoichiometry and stability of the complexes formed between [Pd(Eten)...

Density and Acidic Solution Calorimetry Studies of the 0.333CaO-0.667[xSiO2-(1-x)P2O5] Glassy System

Glassy samples of the 0.333CaO-0.667[xSiO2-(1-x)P2O5] system are prepared by the melt quenching technique. Accurate density and solution enthalpy measurements were performed by pycnometry at 296.15 K and acid solution ca...

XRD ANALYSIS FOR COPPER-GRAPHITE METAL MATRIX COMPOSITES

In the present examination, endeavors have been made for the creation of Cu-graphite MMC by customary and sparkle plasma sintering (SPS) methods. The MMCs were described by x-beam diffraction (XRD). Diverse mechanical pr...

Download PDF file
  • EP ID EP653139
  • DOI 10.24297/jac.v13i10.5870
  • Views 151
  • Downloads 0

How To Cite

Sella Muthu, C Manoharan, R Senthilkumar (2017). THEORETICAL ANALYSIS OF A WET COOLING TOWER FOR FRESH WATER FROM PLUME AND ANALYZING AN INDUSTRIAL COOLING TOWER BASED ON RESULTS. JOURNAL OF ADVANCES IN CHEMISTRY, 13(10), 5892-5898. https://europub.co.uk/articles/-A-653139