User Driven Feedback Control System driven using CAN Protocol

Abstract

Industrial automation is a sector having vast possibilities for major improvements. The system described in this paper consists of a console master computer (CMC) which will monitor various physical nodes usually found in a large industry. The proposed work analyzes the capability of CAN networking which includes data traffic management. The CMC is designed using MATLAB 7.12; the CAN networking is supported using the Vehicular Network Toolbox. The proposed system using CAN has the advantages of being simple in its design which contributes to the overall low cost. The novelty of the work lies in the low cost approach, and fails safe methodology of CAN communication. The proposed system is capable of sending and receiving signals with the additional benefit of feedback mechanism .The proposed work is implementable in any industry with the cost advantage of CAN interface. The proposed work can be used as a cheaper and robust alternative to native technologies like PLC (Programmable Logic Controller). Moreover, the CAN network system is immune from the electrical interferences.

Authors and Affiliations

Ankita Goyal| ECE Department Ujjain Engineering College Ujjain (M.P.), India, Prof. Neha Sharma| ECE Department Ujjain Engineering College Ujjain (M.P.), India

Keywords

Related Articles

Biometric Integration for Improved e-Business Applications

The aim of this project works was to design a framework for biometric authentication and integration scheme by means of biometrics characteristic to secure web applications and E-business authentication to improve se...

Characterization of AF Relaying Systems to Analyze the Ceiling Properties in System Limitations

In recen times, it was shown that transceiver hardware impairments have a harmful impact on the performance of communiqué systems, especially for high-rate systems. The vast majority of technical contributions in the...

Baysian Imaging Concepts for Smart Fracture Detection in X-Ray Images

X-ray imaging is a traditional method for detecting fracture for ages. This project paves way for enhancement rather than replacement of the existing technology. It is a step towards thinking beyond digitization of X-ray...

Handoff Decision Using Fuzzy Logic

The handover or handoff process is of major importance within any cellular telecommunications network. The term handoff refers to the process of transferring an active call or data session from one cell in a cellular...

Can Base Patient Monitoring System

This paper deals with CAN technology to sense and transfer the data related to patient health problem. So, efficient medical services can be provided to the patient in appropriate time. The project is working model wh...

Download PDF file
  • EP ID EP8361
  • DOI -
  • Views 415
  • Downloads 20

How To Cite

Ankita Goyal, Prof. Neha Sharma (2013). User Driven Feedback Control System driven using CAN Protocol. International Journal of Electronics Communication and Computer Technology, 3(5), 468-471. https://europub.co.uk/articles/-A-8361