Uses and Comparison of Multi Input Converter Topology with Power Control

Abstract

In this article a new topology is introduces which shows multiple energy sources input to a common load. But as we know about that all different type of energy sources have different voltage and current characteristic and in DC to DC converter a switching strategy is isolated but in this article we use constant frequency. In 3-level converter there are two uni-directional input power port and a bi-directional port. It have four power switches which control with different duty ratios. In the boost converter topology we use two inductor strategy. The benefit of this technology is the higher voltage gain. In this paper we focused on switching with fixed frequency.

Authors and Affiliations

Chirag Arora

Keywords

Related Articles

Distribution System Power Quality Improvement Using D-STATCOM

Power quality can be explained as the set of limits defined for a system’s electrical parameters so that the whole electrical system can function in its intended manner & performs without significant losses. Power qualit...

Reactive Power Compensation and Power Injection through Distributed Generation Sources

Renewable energy resources are connected in distribution systems to achieving benefits. A control strategy to consummate favor from these grid-interfacing inverters when installed in 3-phase 4-wire distribution systems i...

Uses and Comparison of Multi Input Converter Topology with Power Control

In this article a new topology is introduces which shows multiple energy sources input to a common load. But as we know about that all different type of energy sources have different voltage and current characteristic an...

Comparison of GA and PS Optimization Mechanisms for Optimizing 100MW Delta IV Ughelli Gas Turbine Power Plant Operating Parameters

A comparative analysis for improving the efficiency of 100MW Delta IV Ughelli gas turbine power plant is performed. The study used non-dominated sorting genetic and pattern search algorithms to minimize the objective fun...

Voltage Stability by Injecting Reactive Power using STATCOM for Wind Turbine Squirrel-Cage Induction Generator System during Fault

Reactive power limit of the system affects it’s Voltage stability. The wind driven self excited induction generator during faults and heavy loading condition, lacks in supplying reactive power to the system. FACTs device...

Download PDF file
  • EP ID EP541278
  • DOI -
  • Views 129
  • Downloads 0

How To Cite

Chirag Arora (2018). Uses and Comparison of Multi Input Converter Topology with Power Control. Journal of Advanced Research in Power Electronics & Power Systems, 5(3), 21-23. https://europub.co.uk/articles/-A-541278