Vickers Hardness of Composite Resins Cured with LED and QTH Units

Journal Title: Journal of Dental Biomaterials - Year 2016, Vol 3, Issue 1

Abstract

Statement of Problem: One of the factors affecting the degree of polymerization of light-cured composites is the type of light-curing unit used. In addition, physicomechanical properties of the composite resins depend on the degree of conversion and polymerization. Objectives: Since the type of initiator in new composite resins is not explained by manufacturers, this study is an attempt to compare the depth of hardening, with two LED and QTH light-curing units. Materials and Methods: Fifteen samples prepared from Gradia Direct and Filtek Z250, both of which being universal, were cured with QTH (Astralis 7) and LED (Bluephase C8) light-curing units. All the samples were molded in polyester resin and cut from the middle by a disk. The hardness of the cut area was evaluated at 0, 0.5, 1, 1.5, 2, 2.5, 3, 3.5 and 4-mm depth intervals and also at the same interval as the width of the sample, with Vickers hardness machine, while the sam- ples were placed in a darkroom. Data were statistically analyzed using one-way ANOVA, two-way ANOVA, t-test and post Hoc Tukey’s tests in SPSS, version 16. Results: Filtek Z250 was harder than Gradia Direct at all the depth with both light-curing units. The hardness of Filtek Z250 sample cured with Astralis 7 was higher than that cured with LED, but with Gradia Direct the LED unit resulted in higher hardness. Curing depth was not significantly different between the groups (p = 0.109). Conclusions: Vickers hardness number for both composites used in this study is in an acceptable range for clinical implications. The composites’ composition is important to be considered for selection of light unit. Based on the findings of the present study, LED did not present more curing depth compared with QTH.

Authors and Affiliations

H Alaghemand, M Ramezani, N Zarenejad

Keywords

Related Articles

Effect of Three Common Desensitizers in Reduction of the DentinHypersensitivity after Periodontal Surgery

Statement of Problem: Dentin hypersensitivity is one of the most common c o m p l a i n t s of patients after periodontal treatments which occur after tissue shrinkage. Objectives: The aim of this study was to determine...

A One-Year Evaluation of a Free Fissure Sealant Program

Statement of Problem: Pit and fissure sealant therapy has been approved as an effective measure in the prevention of occlusal dental caries. Resin based ma- terials are the most common materials used worldwide. A variety...

Effect of Caries Removal Methods on the Shear Bond Strength of Resin and Glass IonomerAdhesives to Primary Dentin

Statement of Problem: There is no enough published data about the shear bond strength of resin modified glass ionomer adhesives on caries-affected primary tooth dentin excavated using minimally invasive systems. Objectiv...

Relevance of Micro-leakage to Orthodontic Bonding - a Review

As it is seen, by passing the evolutionary process of banding of orthodontic attachments to the bonding ones, orthodontics have witnessed many developments, such as application of new adhesives, optimized base designs, n...

The Influence of Surface Polish and Beverages on the Roughness ofNanohybrid and Microhybrid Resin Composites

Statement of the Problem: Surface roughness is a key factor in the aesthetics of restorative dentistry as it can determine the clinical quality and success of restorative materials. The chemical process of dissolution in...

Download PDF file
  • EP ID EP248717
  • DOI -
  • Views 67
  • Downloads 0

How To Cite

H Alaghemand, M Ramezani, N Zarenejad (2016). Vickers Hardness of Composite Resins Cured with LED and QTH Units. Journal of Dental Biomaterials, 3(1), 192-198. https://europub.co.uk/articles/-A-248717