Air void system parameters and frost resistance of air-entrained concrete containing calcareous fly ash

Journal Title: Roads and Bridges - Drogi i Mosty - Year 2013, Vol 12, Issue 1

Abstract

The paper presents results of the investigation of the air void characteristics and the resistance to cyclic freezing and thawing of air-entrained concrete containing calcareous fly ash. The frost resistance was tested also under the presence of de-icing salts to check the resistance to frost-salt scaling and without de-icing salts. The range of investigation included air entrained concrete mixes with the specified water-binder ratio of [i]w[/i]/[i]b[/i]=0.45 with addition of calcareous fly ash or made using blended cements with calcareous fly ash (W), and also siliceous fly ash (V) and ground granulated blast-furnace slag (S). The coarse aggregates used were crushed granodiorite and crushed limestone. The air-void system parameters were determined by microscopic image analysis and the effect of addition of calcareous fly ash was assessed. The effect of concrete age and presence of fly ash W on the strength and freeze-thaw resistance was also studied. The tests have shown that the use of calcareous fly ash as one of the main constituents of blended cements does not affect the frost salt scaling resistance nor the resistance to internal frost damage provided that the air void system is adequate.

Authors and Affiliations

Mariusz Dąbrowski, Michał Glinicki

Keywords

Related Articles

Pandora - metoda wyceny społecznych kosztów zdarzeń drogowych w Polsce

Tematem artykułu jest metoda wyceny społecznych kosztów wypadków i kolizji drogowych w Polsce, opracowana w Zakładzie Ekonomiki Instytutu Badawczego Dróg i Mostów. Koszty ekonomiczne, obok strat osobowych (wyrażonych fiz...

Hydrated lime effect on rutting resistance of sma pavements

The paper summarises results of examination of binder extracted from an incorporated SMA mixture with hydrated lime, and from a control mixture containing fatty acid amine, according to the American procedure MSCR defini...

Impact of reinforcement layer material and thickness on deflections measured in the static and dynamic plate load tests

The bearing capacity and compaction values obtained in the plate load tests (the latter determined indirectly) often depend on the used test method: static - using static load test apparatus (VSS) or dynamic - using ligh...

Badania nowego typu systemu ważenia pojazdów drogowych w ruchu

W pracy zaprezentowano wstępną ocenę nowej metodologii stosowanej do identyfikacji obciążeń wywieranych przez przejeżdżające pojazdy na nawierzchnię drogi. Proponowane rozwiązanie opiera się na pomiarze lokalnych odkszta...

Właściwości betonów na cementach zawierających popiół lotny wapienny

W artykule przedstawiono wyniki badań właściwości betonów wykonanych z jedenastu cementów zawierających popiół lotny wapienny. Jako układ odniesienia przy ocenie ich właściwości przyjęto właściwości betonów o takich samy...

Download PDF file
  • EP ID EP69455
  • DOI 10.7409/rabdim.013.004
  • Views 127
  • Downloads 0

How To Cite

Mariusz Dąbrowski, Michał Glinicki (2013). Air void system parameters and frost resistance of air-entrained concrete containing calcareous fly ash . Roads and Bridges - Drogi i Mosty, 12(1), 41-55. https://europub.co.uk/articles/-A-69455