Aplikasi Filter Pasif pada Beban Inverter Tiga Fase Berbeban

Abstract

Harmonic is one of sinusoidal components, one wave period from which having multiple frequency of its fundamental frequency one, leading to electrical power quality problems. Harmonic distortion in term of voltage and current ones, generally is due to non linier impedance. Inverter is one of example of it. The result of the tests were showed that voltage harmonic distortion at inverter did not exceed the IEEE 519-1992 maximum limitation of 5%. While current harmonic distortion for each phase exceed 102,3%, 89,94% and 72,67%. After using passive filter, the total harmonic distortion (THD) current became 5,458 %, 6,118% and 5,968% for each phase.

Authors and Affiliations

Wahri Sunanda

Keywords

Related Articles

Sistem Detektor Kebakaran untuk Rumah Susun dengan Sistem Wireless Sensor Network

Fire is one disaster that often leads to the large amount of material losses and casualties. This is partly due to the lack of support tools provided by residential buildings. There are two kinds of systems of fire prote...

Analisa Kinerja PAPR pada Sistem OWDM Menggunakan Wavelet Packet

In wireless communications, demand to provide high-speed data services with good performance raises new techniques to increase spectrum efficiency and improved signal quality due to frequency selective fading. OFDM is a...

Optimasi Jaringan 4G LTE (Long Term Evolution) pada Kota Balikpapan

Long Term Evolution (LTE) is a fourth generation (4G) technology developed by the 3rd Generation Partnership Project (3GPP). LTE is capable of providing downlink speeds of up to 100 Mbps and 50 Mbps uplink. This research...

Pengaruh Ketidakseimbangan Beban Terhadap Stabilitas Steady State

The stability of the electric power system is related to the balance of power in the system. When a power change occurs, the rotor will swing affecting the power angle, rotation speed, frequency and stability of the syst...

Analisa Pengendali Hybrid Sliding Mode Control dan PID Untuk Mengendalikan Concentration pada Isothermal Continuous Stirred Tank Reactor (CSTR)

Systems in industry often occur in performance or desired performance. One of them isothermal CSTR system where the system has not been able to work according to the desired set point 1 g.mol / litter, to achieve the set...

Download PDF file
  • EP ID EP549023
  • DOI 10.33019/ecotipe.v1i1.45
  • Views 66
  • Downloads 0

How To Cite

Wahri Sunanda (2014). Aplikasi Filter Pasif pada Beban Inverter Tiga Fase Berbeban. Jurnal Ecotipe (Electronic, Control, Telecommunication, Information, and Power Engineering), 1(1), 42-48. https://europub.co.uk/articles/-A-549023