Bezpieczna zamiana inhalatorów suchego proszku (DPI)

Journal Title: Alergia - Year 2017, Vol 0, Issue 1

Abstract

Interchangeability of DPI’s at the level of the pharmacy or by other health providers is a fact. The decision to do this usually falls apart from the initial health provider who prescribed the initial inhalation therapy. The interchangeability of DPI’s is especially important due to the fact that each DPI should be individually dispensed to the patient. In order to explain this complicated issue the process of generating a medicinal aerosol is discussed in detail, with emphasis on aerozolization, deaggregation, penetration and deposition, all depending on the inspiratory maneuver of the patient. This detailed complex process underlines the need to carefully assess any decision to interchange a DPI, especially in patients with very low inspiratory flow (young children, acute obstructed, asthma and COPD patients). Registration processes of generic DPI’s with emphasis to the interchangeability of such devices in discussed. The detailed process of making such a decision is shown on the example of the Easyhaler® DPI, which has proven to be interchangeable in such cases. ............................... Zamiana jednego inhalatora produktu leczniczego na drugi jest coraz bardziej powszechna. Decyzja o takiej zamianie często zapada poza kontrola lekarza pierwotnie planującego terapię jak i samego chorego. Szczególnie trudne jest to zagadnienia w przypadku zamiany jednego inhalatora suchego proszku (DPI) na drugi. Dla pełnego zrozumienia istoty problemu zamiany przedstawiono dokładnie proces powstawania aerozolu leczniczego w przypadku DPI. Uwzględniono procesu aerozolizacji, deagregacji i deponowania cząstek leczniczego aerozolu. Omówiono wpływ oddechu na proces generowania aerozolu. W skrócie przedstawiony sposób generowania aerozolu przez DPI podkreśla trudności w swobodnej zamianie inhalatorów suchego proszku. Omówiono na przykładzie inhalatora Easyhaler® jakie warunki musi spełnić inhalator aby mógł być swobodnie zamieniany na inny.

Authors and Affiliations

Michał Pirożyński

Keywords

Related Articles

Przewlekłe zapalenie błony śluzowej nosa i zatok czy astma

One of the four cardinal symptoms in chronic rhinosinusitis in children is cough. This symptom also occurs in asthma. In chronic rhinosinusitis post nasal-drip syndrome is a common cause of chronic cough and wheezing. Th...

Tajemnicze krętki Borrelia burgdorferi

Borrelia burgdorferi sensu lato genospecies spirochetes are long, spiral Gram-negative bacteria that infects a wide variety of mammals, birds and reptiles. Borrelia burgdorferi sensu stricto – Borrelia burgdorferi, Borre...

Diagnostyka molekularna w alergii na pokarmy

Molecular diagnostic techniques have been practically used in allergology for over 10 years. The paper discusses the importance of molecular diagnostics in the food allergy diagnosis. The capabilities of the method and i...

Easyhaler® - czym się wyróżnia na tle innych DPI?

DPI (dry powder inhalers) underwent a tremendous development as a consequence of the Montreal Protocol banning freons in pMDIs. The inhalable particles ranging from 2 to 5 μm deposit in the 6 – 7 generation of airways, t...

Długie niekodujące RNA jako czynniki modyfikujące odpowiedź alergiczną

Long non-coding RNA (lncRNA) are regulatory RNAs, and the recent data indicate that they may play a role in the differentiation of dendritic cells and regulatory T cells as well as the activation of CD4+ cells, crucial i...

Download PDF file
  • EP ID EP457660
  • DOI -
  • Views 155
  • Downloads 0

How To Cite

Michał Pirożyński (2017). Bezpieczna zamiana inhalatorów suchego proszku (DPI). Alergia, 0(1), 44-46. https://europub.co.uk/articles/-A-457660