CALIBRATION OF EXTREMELY SENSITIVE RANGES OF DC PICOAMMETERS WITH ANALOG ACTIVE I/U CONVERSION
Journal Title: Metrology and Measurement Systems - Year 2005, Vol 12, Issue 1
Abstract
The paper deals with the problem of calibration of extremely sensitive picoammeters with measuring ranges close to limits of the measuring possibilities. The presented method of calibration bases on a resistive source of very low DC standard current, namely a current calibrator. Procedure for the design of a proper calibrator, criteria of optimal selection of high value resistance standards and a detailed analysis of the accuracy of obtained calibrating current have been described. The principle of evaluation of measurement uncertainty and method of assessment of combined uncertainty for calibrated picoammeters with analog and digital display have been introduced. It has been shown that in an averagely equipped measuring and research laboratory and using relatively simply accessible resistance standards with values of 1010 - 1011 Ω, it is possible to calibrate the most sensitive ranges of picoammeters with active i/u conversion.
Authors and Affiliations
ZBIGNIEW KŁOS
ADVANCED NANOMETROLOGY TECHNIQUES OF CARBON NANOTUBES CHARACTERIZATION
It has become evident that carbon nanotubes (CNTs) possess exceptionally high physical, mechanical, electrical, and structural properties that made them attractive for researchers to investigate. In this paper, CNTs synt...
ANALYSIS OF INFLUENCE OF INTERNAL CONVERTERS NONLINEARITY ON INTELLIGENT CYCLIC ADC PERFORMANCE
The task of the paper is the presentation of a modelling approach to quantitative analysis of the influence of internal converter nonlinearities on the performance of sub-optimal intelligent cyclic A/D converters (IC ADC...
COMPARISON OF LS-TYPE METHODS FOR DETERMINATION OF OLIVE OIL MIXTURES ON THE BASIS OF NIR SPECTRAL DATA
The spectrophotometric analysis of oil mixtures, containing olive oil, is the subject of this paper. Its objective is to compare six least-squares-type estimators which are potentially applicable for determination of a...
MEASUREMENT METHOD OF SHAPE DEVIATION OF CYLINDRICAL MICRO-LENSES USING FOCUSED LASER BEAM AND REFERENCE AXIS<br />
Constant progress in application of micro-lenses in many modern optical systems caused a continuous increase of the need to investigate methods of their measurement. A new method of measurement of shape deviation of such...
MEASUREMENT OF LUMINESCENCE IN COLOURED PRINTED MATERIALS
While fluorescent pigments have been used for many years, the formulation and quality control of coloured printed materials containing them, has been a challenge, primarily due to lack of appropriate instrumentation at a...