CONTROL OF DOUBLY FED INDUCTION GENERATOR AT GRID VOLTAGE IMBALANCE

Journal Title: Power Electronics and Drives - Year 2017, Vol 2, Issue 2

Abstract

The paper presents properties and control of doubly fed induction machine operating under unbalanced grid voltage conditions. The proposed method does not include symmetrical se-quences decomposition and is realized in a rotating frame not synchronized with the grid voltage vector or the stator flux vector. The method uses reference torque and reference q component of instantaneous power for calculation of the reference stator current. Next, calculation of magnetizing current for the given unbalanced grid voltage is used to assign reference rotor current. Due to the fact that reference current contains both positive and negative sequence, the proportional-integral-resonant controller is used. The main strategy is non-oscillatory waveform of torque, whereas other strategies like symmetrical stator current or sinusoidal rotor current can easily be obtained by adequate filtration of the reference values. The paper presents simulation results of 2MW model of doubly fed induction generator and the laboratory tests with the use of small scale 7.5kW machine.

Authors and Affiliations

Grzegorz Iwański, Tomasz Łuszczyk

Keywords

Related Articles

APPLICATION OF ARTIFICIAL BEE COLONY ALGORITHM TO AUTO-TUNING OF STATE FEEDBACK CONTROLLER FOR DC-DC POWER CONVERTER

Background: The article presents auto-tuning method of state feedback voltage controller for DC-DC power converter. Material and methods: Simulation and experimental tests prove proper operation of proposed auto-tuning m...

PARAMETRIC - ACTIVE COMPENSATION OF EARTH FAULT CURRENT IN IT-TYPE NETWORK

Parametric-active compensation of earth leakage currents minimalized virtual capacitance current in ships IT-type network is discussed. The protection is based on automatic compensation of leakage earth currents. The pro...

Performance and Stability Analysis of Series Cascaded High gain Interleaved Boost Converter for Photovoltaic applications

Interleaved boost converters (IBC) are cascaded with more numbers in parallel for most of the applications. A novel approach is attempted to connect IBC in series cascaded. The maximum advantage of IBC has when it is ope...

FINITE-ELEMENT ANALYSIS OF ACCIDENTAL ENERGIZING OF AN OFF-LINE TURBOGENERATOR

Background: Presented article shows the computation results of accidental off-line turbogenerator energizing. Inadvertent energizing of turbogenerator has been a particular issue in the power plant. The investigated case...

Dynamic Performance of Estimator-Based Speed Sensorless Control of Induction Machines using Extended and Unscented Kalman Filters

This paper presents an estimator-based speed sensorless field oriented control (FOC) method for induction machines, where the state estimator is based on a self-contained, non-linear model. This model characterizes both...

Download PDF file
  • EP ID EP408006
  • DOI -
  • Views 67
  • Downloads 0

How To Cite

Grzegorz Iwański, Tomasz Łuszczyk (2017). CONTROL OF DOUBLY FED INDUCTION GENERATOR AT GRID VOLTAGE IMBALANCE. Power Electronics and Drives, 2(2), -. https://europub.co.uk/articles/-A-408006