Development and Validation of Simplified RP-HPLC Method for Quantification of Candesartan Cilexetil in Commercial Formulations

Journal Title: Der Pharma Chemica - Year 2024, Vol 16, Issue 1

Abstract

In order to produce antihypertensive effects, Candesartan Cilexetil (CC), a candesartan inactive prodrug, was quickly converted into active candesartan after absorption in the Gastrointestinal (GI) tract. This research study describes the development and validation of an accurate, precise, repeatable, easy and speedy Reverse-Phase High-Performance Liquid Chromatography (RP-HPLC) approach for measuring CC in a formulation using reverse-phase HPLC. In this study, liquid chromatography was performed on a Zorbax SB C-18 analytical column with dimensions of 2504.6 mm, 5 m, using a mobile phase consisting of Acetonitrile (ACN) and 0.1 percent orthophosphoric acid (pH 2.5) in a ratio of 35:65 vol/vol as the mobile phase. Results were presented as mean Standard Deviation (SD). This experiment used an injection volume of 20 microliters to measure the sample at 258 nano liters per minute while using a flow rate of 1.5 microliters per minute. 4.2 minutes was determined to be the retention time for both the reference and sample drugs. There was no evidence of nonlinearity in the calibration curve for CC when the concentration ranged from 50 ppm to 160 ppm and the Regression coefficient (R2 ) was determined to be 0.9996. When the percentage recovery of CC was achieved, it was in the range of 98.10 percent to 98.70 percent, indicating that the present approach was very accurate. Recovery trials using Percent Relative Standard Deviation (percent RSD) with intra and inter-day accuracy were found to be less than 2 percent, demonstrating that the established procedure is repeatable. The technique was verified in accordance with the International Conference on Harmonization (ICH) requirements and may be highly recommended for regular analysis of CC due to the fact that it is the most reliable and quick methodology currently available. Despite the fact that a great deal of research has been done on calculating CC in dosage forms, this study was determined to be under green chemistry conditions, as well as being quick and inexpensive. As a result, the statistical validation of the data revealed that the suggested approach may be used to estimate the CC in commercial formulations, which is encouraging.

Authors and Affiliations

Sachin Kothawade1 Rashmi Tambare Vishal Pande Rucha Pardeshi1 Sandesh Bole1 Pranaya Misar Balireddy Keesara Prachi Kanawade Kanchan Jadhav5 Vijaya Padwal Amit Lunkad and Manjusha Bhange

Keywords

Related Articles

Current Trends for Regulatory Requirements of Elemental Impurity in Drug Substance for Regulatory Market

The presence of elemental impurities in drug substances has gained increasing attention in the pharmaceutical industry due to their potential impact on product safety and efficacy. Regulatory agencies worldwide have esta...

In-Situ Gel Systems for Ocular Therapeutics: Unveiling the Impact of Polymer Selection

A major problem in ocular therapeutics is the attainment of optimal drug concentration at the site of action, which is mainly due to precorneal loss resulting in only a small fraction of the drug being ocularly absorbed....

Curcumin and Ascorbic Acid Therapeutic Benefits in a Female Wistar Rat with Renal Tissue UVB-Induced Hyperthyroidism: A Histological and Biochemical Study

Renal issues are a major problem for humanity. The renal system may sustain damage from the potentially dangerous radiation. Therefore, the purpose of this study is to evaluate how well curcumin and ascorbic acid protect...

Microsponge: An Innovative and Novel Strategy for Drug Delivery System

The microsponge approach has become a highly competitive and rapidly evolving technology. They are porous, highly cross-linked, polymeric microspheres that can be efficiently incorporated into topical drug delivery syste...

Requalification of Friability Testing Apparatus

Re-qualification as a part of validation is the task performed to identify or check that utilities, equipment and ancillary systems can operate within limits for their intended use. Equipment qualification is a key eleme...

Download PDF file
  • EP ID EP742481
  • DOI 10.4172/0975-413X.16.1.197-203
  • Views 14
  • Downloads 0

How To Cite

Sachin Kothawade1 Rashmi Tambare Vishal Pande Rucha Pardeshi1 Sandesh Bole1 Pranaya Misar Balireddy Keesara Prachi Kanawade Kanchan Jadhav5 Vijaya Padwal Amit Lunkad and Manjusha Bhange (2024). Development and Validation of Simplified RP-HPLC Method for Quantification of Candesartan Cilexetil in Commercial Formulations. Der Pharma Chemica, 16(1), -. https://europub.co.uk/articles/-A-742481