Evaluation of Impression Accuracy Making with Different Kind of Tray

Journal Title: Scholars Journal of Applied Medical Sciences - Year 2016, Vol 4, Issue 7

Abstract

The aim of this study was to evaluate how tray shape (half or full arch) and impression procedure affect the precision of impressions.Half arch and full arch trays in metal and plastic were utilized in combination with a two stage impression technique. For each technique-tray combination, 10 impressions were made of a master cast with two steel rod representing the mandibular left first premolar and first molar, where a standard steel rod was placed. Each steel abutment had four marks, which served as a reference point. With a universal measuring microscope, the x-, y-, and z-coordinates were computed for each mark on the master cast and impressions. The span between marks and the reference point on the impressions were calculated and compared with those of the master cast.All techniques employed with the full arch metal trays and the plastic trays had distances that were not significantly different from the master cast ( P < 0.05), while for the half arch plastic trays, it was different from the distance in master cast but the distances were not significantly different from the master cast ( P < 0.05).Half arch plastic trays produced correct impressions. When full arch were employed, the full arch metal tray impressions were dimensionally better than full arch plastic impressions. Keywords:impression procedure, tray shape, plastic trays mandibular teeth

Authors and Affiliations

Arash Shisheyan, Hamed Amrai, Dr. Zahra Ali Puriyani, Saeid Shirshahi

Keywords

Related Articles

Peripheral Arterial Disease in Proven Coronary Artery Disease

Abstract: Peripheral arterial disease (PAD) is a predictor of cardiovascular morbidity and mortality leading to adverse outcome. It is a marker of increased risk of cardiovascular events in patients with coronary arteria...

Vestibular Activation by Sound in Human

It has been established that the seismic sensitivity of the human vestibular system exceeds that of the cochlea for low-frequencies. The objective of this work is to determine spurious low frequency air bone gap (slABG)...

A Clinical Study on the Effect of Yoganjana in the Treatment of Praklinnavartma w.s.r. to Blepharitis

The present study was carried out to assess the effect of Yoganjana in the treatment of Praklinnavartma (Blepharitis). There are 21 Vartmagata rogas, out of which Praklinnavartma is a most common ocular disorder. It is a...

Effective simulation training for advanced cardiopulmonary resuscitation for first year students of a nursing university

The first year students in the Juntendo University Faculty of Health Science and Nursing have undertaken an Immediate Cardiac Life Support (ICLS) course. However, this study confirmed the degradation of knowledge on car...

A prospective study of 15 patients with Kaplan's like variant of distal femoral epiphysiolysis

Epiphysiolysis is an uncommon injury which is fraught with complications. Completely separated physical fractures of distal femur invariably need osteosynthesis with open reduction and fixation to prevent redisplacement....

Download PDF file
  • EP ID EP371334
  • DOI -
  • Views 36
  • Downloads 0

How To Cite

Arash Shisheyan, Hamed Amrai, Dr. Zahra Ali Puriyani, Saeid Shirshahi (2016). Evaluation of Impression Accuracy Making with Different Kind of Tray. Scholars Journal of Applied Medical Sciences, 4(7), 2412-2416. https://europub.co.uk/articles/-A-371334