Impact of Prolonged Fraction Delivery Time Modelling Stereotactic Body Radiation Therapy with High Dose Hypofractionation on the Killing of Cultured ACHN Renal Cell Carcinoma Cell Line
Journal Title: Journal of Biomedical Physics and Engineering - Year 2017, Vol 7, Issue 3
Abstract
Introduction: Stereotactic body radiotherapy delivers hypofractionated irradiation with high dose per fraction through complex treatment techniques. The increased complexity leads to longer dose delivery times for each fraction. The purpose of this study is to investigate the impact of prolonged fraction delivery time with high-dose hypofractionation on the killing of cultured ACHN cells. Methods and Materials: The radiobiological characteristics and repair half-time of human ACHN renal cell carcinoma cell line were studied with clonogenic assays. A total dose of 20 Gy was administered in 1, 2 or 3 fractions over 15, 30 or 45 min to investigate the biological effectiveness of radiation delivery time and hypofractionation. Cell cycle and apoptosis analysis was performed after 3-fraction irradiation over 30 and 45 min. Results: The α/β and repair half-time were 5.2 Gy and 19 min, respectively. The surviving fractions increased with increase in the fraction delivery time and decreased more pronouncedly with increase in the fraction number over a treatment period of 30 to 45 min. With increase in the total radiation time to 30 and 45 min, it was found that with the same total dose, 2- and 3-fraction irradiation led to more cell killing than 1-fraction irradiation. 3-fraction radiation induced G2/M arrest, and the percentage of apoptotic cells decreased when the fraction delivery time increased from 30 min to 45 min. Conclusion: Our findings revealed that sublethal damage repair and redistribution of the cell cycle were predominant factors affecting cell response in the prolonged and hypofractionated irradiation regimes, respectively.
Authors and Affiliations
M Khorramizadeh, A Saberi, P Shokrani
Optimized Blood Volume Monitoring during Hemodialysis Procedure based on Ultrasonic Speed Measurement
Fast reduction of blood water volume due to ultra-filtration via hemodialysis machine and critical threshold of blood water volume can result in clinical complications such as hypotension. When blood water volume reduces...
Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs
LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support...
Signal Intensity of High B-value Diffusion-weighted Imaging for the Detection of Prostate Cancer
Background: Diffusion-weighted imaging (DWI) is a main component of multiparametric MRI for prostate cancer detection. Recently, high b value DWI has gained more attention because of its capability for tumor characteriza...
Synergistic Effects of NDRG2 Overexpression and Radiotherapy on Cell Death of Human Prostate LNCaP Cells
Background: Radiation therapy is among the most conventional cancer therapeutic modalities with effective local tumor control. However, due to the development of radio-resistance, tumor recurrence and metastasis often oc...
Dosimetry of Critical Organs in Maxillofacial Imaging with Cone-beam Computed Tomography
Background: While the benefits of cone-beam computed tomography (CBCT) are well known in maxillofacial imaging, the use of this modality is not risk-free. Objective: The aim of this study was to evaluate the exposure dos...