Indexes of Foamed Warm Mixed Crumb Rubber Modified Asphalt
Journal Title: 河南科技大学学报(自然科学版) - Year 2016, Vol 37, Issue 3
Abstract
For the study of low temperature performance of foamed warm mixed crumb rubber modified asphalt and evaluation indexes,the ductility test,bending beam rheometer( BBR) test and dynamic shear rheological test were conducted on foamed warm mixed crumb rubber modified asphalt and styrene-butadiene-styrene( SBS) modified asphalt. The rationality of the low temperature performance index of foamed warm mixed rubber asphalt was evaluated by using the ductility value,the creep strength modulus S and glass transition temperature Tg. The creep strength modulus S and the glass transition temperature Tgshow that the low temperature performance of foamed warm mixed crumb rubber asphalt is better than that of foamed warm mixed SBS modified asphalt in low temperature. However,the ductility value data show different conclusion. Through analysis,ductility index is not suitable for evaluating low temperature performance of foamed warm mixed crumb rubber modified asphalt binder,while the glass transition temperature Tgis feasible as the evaluation index.
Authors and Affiliations
Fan GU, Bo XU, Kai WANG
Preparation of Fluorophlogopite Glass-ceramic Powder by Sol-gel Method
Taking Mg ( NO3) _2·6H2O, Al ( NO3) _3·9H2O, NH4 F, NaF, CO ( NH2) _2and silica sol as raw materials, the powder of fluorophlogopite ( NaMg3AlSi3O10F2) was prepared by sol-gel method. The effects of the heat treatment te...
Chance Constraint Model and Properties of Uncertain Random Closed-loop Logistics Network
1
Experiment and Microcosmic Mechanism Analysis of Manganese Slag Powder Modified Asphalt Performance
The 35 μm particle size of manganese slag powder was mixed into 70#road petroleum asphalt according to the powder oil ratio of 0%, 3%, 6%, 9%, 12% and 15% to prepare the manganese slag powder asphalt. The test of penetra...
Experiment on Compressive Properties of Ice with Cotton Fiber
The universal material testing machine was used to measure uniaxial compressive strength of ice with fiber mass fraction 0%,3%,6%,9%,12% respectively over a strain rate range from 10-3/ s to 10-1/ s. The stress strain cu...
Size Effect of Glass Fiber Reinforced Plastic Confined Concrete Column
Three glass fiber reinforced plastic( GFRP) confined reinforced concrete columns and three unconfined reinforced concrete columns were tested and the finite element analysis was carried out on 15 specimens. The influence...