MEASUREMENT OF TEMPERATURE DEPENDENCE OF FACTORS OF ABSORPTION EFFICIENCY OF PLATINUM BOLOMETER ON RADIATION WAVELENGTH 1.06 MICRON

Abstract

The method of temperature dependence measurement of factor of absorption efficiency of thin-wire platinum bolometer for E- and H-polarized radiation is grounded and experimentally checked taking into account intense distribution unevenness. Measurements have been carried out for platinum bolometers on the neodymium laser with wavelength 1.06 microns.

Authors and Affiliations

S. V. Pogorelov, B. V. Safronov, V. P. Balkashin, I. А. Priz

Keywords

Related Articles

RELATIVISTIC APPROACH TO CALCUATION OF IONIZATION CHARACTERISTICS FOR RYDBERG ALKALI ATOM IN A BLACK-BODY RADIATION FIELD

The combined relativistic energy approach and relativistic many-body perturbation theory with the zeroth Dirac-Fock-Sham approximation are used for computing the thermal Blackbody radiation ionization characteristics of...

ANALYZING THE MAGNETIC CIRCUIT OF AN EDDY CURRENT SENSOR TAKING INTO ACCOUNT THE SPEED OF A MOVING NON-MAGNETIC SHEET LOCATED IN THE WORKING GAP

A method for calculating the magnetic circuit of ECP taking into account the movement speed and the thickness of the magnetic conducting sheet in the gap is introduced. An analytical expression for the output voltage of...

ELECTROMAGNETIC WAVES RADIATOR WITH CONTROLLED CHARACTERISTICS

The problem of Н-sectorial horn-type radiator parameter improvement – the width of the main directional lobe (DL), side lobe level reduction, DL form monitoring with the help of a covering of an internal radiator cavity...

THE QUASI BALANCED CONDUCTOMETRIC BRIDGE FOR BIOSENSOR SYSTEM WITH BALANCING MODULUS AND PHASE

The AC bridge for differential conductometric biosensor system is discussed, which may be installed in a quasi-balanced state with a non-zero output, but balanced for common mode noise on the conductometric transducers e...

HETEROLAYERS OF ANISOTROPIC Α-ZNSE FOR PHOTOSENSORS

The optical, luminescence and electrical properties of α-ZnSe heterolayers obtained by the method of isovalent replacement are investigated. The high quantum yield of luminescence η = 10-12% in the short-wave region is e...

Download PDF file
  • EP ID EP399628
  • DOI 10.18524/1815-7459.2014.2.108175
  • Views 62
  • Downloads 0

How To Cite

S. V. Pogorelov, B. V. Safronov, V. P. Balkashin, I. А. Priz (2014). MEASUREMENT OF TEMPERATURE DEPENDENCE OF FACTORS OF ABSORPTION EFFICIENCY OF PLATINUM BOLOMETER ON RADIATION WAVELENGTH 1.06 MICRON. Сенсорна електроніка і мікросистемні технології, 11(2), 40-46. https://europub.co.uk/articles/-A-399628