NTERCOMPARISON OF WATER TRIPLE POINT CELLS FROM INTIBS AND INRIM
Journal Title: Metrology and Measurement Systems - Year 2008, Vol 15, Issue 4
Abstract
The triple point of water defines the unit of thermodynamic temperature, kelvin, and is the most important fixed point of the International Temperature Scale of 1990. Several international comparisons of cells for the realization of the water triple point were carried out to estimate the temperature values obtained in real conditions at national metrology institutes. A separate bilateral comparison was set up for INTiBS, Poland with INRiM, Italy, as CCT-K7 participant, in order to create a direct reference to CCT-K7 for the Polish institute. Results of the bilateral comparison carried out as EUROMET project no 895 are presented in this paper.
Authors and Affiliations
A. Szmyrka-Grzebyk, L. Lipiński, Peter Steur, R. Dematteis
DIGITAL MEASUREMENT OF TRANSIENT DISTURBANCES IN ELECTRIC POWER NETWORK WITH ADDITIONAL LOWPASS ANALOG CIRCUIT<br />
The paper presents a DSP-based system for measurement of the short-term transient distortions in electric power networks. These distortions typically possess short duration times and high amplitude values and thus they a...
INTELLIGENT MEASURING SYSTEM FOR CHARACTERISATION OF DEFECT CENTRES IN SEMI-INSULATING MATERIALS BY PHOTOINDUCED TRANSIENT SPECTROSCOPY
An intelligent measurement system for the characterisation of defect centres in semi-insulating materials is presented. The system utilises two-dimensional analysis of the photocurrent transients digitally recorded in a...
NOVELTIES IN ELECTRICAL MEASUREMENTS AND INSTRUMENTATION<br /> IN THE WAKE OF IMEKO TC4 & TC 19 SYMPOSIA AND ADC WORKSHOP<br /> IN IASI, ROMANIA, SEPTEMBER 2007
From 18 to 22 September 2007, at the Technical University “Gh. Asachi” of Iasi, Romania, there took place undoubtedly important scientific events, held under the auspices of the International Measurement Confederation....
MEASURE OF ELECTRIC REACTIVE POWER
Generated electric power can either be dissipated or occur in the form of an electric field and a magnetic field. By replacing the voltage in the well-known equation for dissipated power (energy) with its derivative (a f...
COMPARISON BETWEEN SIMPLE POLYNOMIALS AND AN ITS-90 BASED REFERENCE FUNCTIONS OF EMF VS. TEMPERATURE RELATION FOR HIGH PURITY NOBLE METAL THERMOCOUPLES
Emf versus temperature reference polynomial functions covering the temperature range from 100° C up to 960° C have been developed for three types of noble metal thermocouples, which are Pt-10%Rh/Pt, Au/Pt and Pt/Pd. Our...