Optimal Placement of Multiple Distributed Generation to Improve Voltage Stability as well as Minimize Loss in Distribution System

Abstract

Theaim of paper is to presents a technique based on Particle Swarm Optimization (PSO) to identify the switching operation plan for feeder reconfiguration and optimum size value of DG simultaneously. The key purpose is to diminish the real and reactive power losses and improve the bus voltage profile in the system while satisfying all the distribution constraints. A method based on PSO algorithm to find out the minimum formation is presented and their impact on the network real power losses and voltage profiles are investigated. The results are obtained through MATLAB coding.

Authors and Affiliations

Neeraj Kumar Kushwaha, Abhishek Singh

Keywords

Related Articles

An Endeavor of Frequency Regulation by Free Governor Mode of Operation in Bangladesh Power System

For satisfactory, secured and economic operation of a power system, the frequency should remain nearly constant. The only way to maintain system frequency within an acceptable range is to make balance between generation...

Comparative Analysis of Integrating WECS with PMSG and DFIG Models connected to Power Grid Pertaining to Different Faults

In the present centaury wind propelled power generator has become the most challenging with the power system in terms of power quality and harmonic distortion control. These challenges are now overtaken by the advancemen...

Efficient Anti-Jamming Technique Based on Detecting a Hopping Sequence of a Smart Jammer

Military wireless communications have always been involved in the improvement of secured tactical Communications. However, securing such networks on a battlefield is far from being simple since wireless jamming attack ca...

Power Quality Issues of Single Phase PFC Low Frequency Active Converter

The equipment connected to an power distribution network usually needs some kind of power conditioning, typically rectification, which produces a non-sinusoidal line current due to the non-linear input characteristic. Wi...

Diffusion-thermo and Aligned Magnetic Field Effects on Free Convection on Flow past an Inclined Porous Plate with First Order Chemical Reaction

A theoretical analysis is carried out to study the heat and mass transfer flow of viscous incompressible fluid past an inclined porous plate with the aligned magnetic field and Diffusion-thermo effects. A uniform magneti...

Download PDF file
  • EP ID EP388781
  • DOI 10.9790/1676-1303030106.
  • Views 134
  • Downloads 0

How To Cite

Neeraj Kumar Kushwaha, Abhishek Singh (2018). Optimal Placement of Multiple Distributed Generation to Improve Voltage Stability as well as Minimize Loss in Distribution System. IOSR Journals (IOSR Journal of Electrical and Electronics Engineering), 13(3), 1-6. https://europub.co.uk/articles/-A-388781