PERFORMANCE ASSESSMENT OF "FIELD PROGRAMMABLE ANALOG ARRAYS"
Journal Title: Metrology and Measurement Systems - Year 2007, Vol 14, Issue 4
Abstract
Field Programmable Analog Arrays (FPAAs) are reconfigurable analog modules introduced on the electronic market in the last decade. Their operation and, in particular, their programmability is achieved owing to the use of switched capacitors technology. At least in principle, they seem to be a very attractive and powerful tool to design analog circuits whose parameters have to be tuned to signal variations as in carrying out sensor conditioning systems. But the aim of exploiting their possibilities in the field of metrology requires complete characterization and performance assessment of the involved building blocks. With this goal, in the paper, the metrological characterization of the most commonly blocks to be used in analog conditioning circuits, such as amplifiers and filters, is performed. These blocks have been characterized in terms of both frequency response and step response and the obtained experimental results have been compared with those expected from theoretic analysis. Concluding remarks are then deduced to furnish practical hints in the use of FPAAs in measurement applications.
Authors and Affiliations
ALDO BACCIGALUPI, ANNALISA LICCARDO
THE POROACCESSIBILITY PARAMETERS FOR THREE-DIMENSIONAL CHARACTERIZATION OF ORTHOPAEDIC IMPLANTS POROUS COATINGS<br />
The ability of formation of the proper bone-porous implant fixation depends, among others, on the structural-osteoinductive properties of the porous coating covering the orthopaedic implant surface. These properties, des...
ANALYSIS OF THE IRREGULARLY SAMPLED SIGNALS ABOVE THE NYQUIST LIMIT
A new method of spectrum analysis of the nonuniformly sampled data above the Nyquist limit is proposed, which is based on the digital spectral shift to the baseband, optional filtering and the subsequent spectrum analysi...
SEVERAL APPROACHES TO ADC TRANSFER FUNCTION APPROXIMATION AND THEIR APPLICATION FOR ADC NON-LINEARITY CORRECTION
The performance of current electronic devices is mostly limited by analog front-end and analog-to-digital converter's (ADC) actual parameters. One of the most important parameters is ADC nonlinearity. The correction of t...
THE INFLUENCE OF INACCURACY OF CALCULATING ALGORITHMS USED IN THE CMMS ON MEASUREMENT RESULTS -FINAL REPORT<br />
The author has devised a test for evaluating the accuracy of calculation algorithms and used it to establish the accuracy of the software of fourteen CMMs offered by world top manufacturers. Using a minimum number of mea...
NEW INSTRUMENTS TO MEASURE PARAMETERS OF INFRA-LOW FREQUENCY VOLTAGE SIGNALS<br />
The paper presents the design, the principles of operation and the technical specification of two types of infra-low frequency voltage instruments: the integrating converter instrument and the microprocessor instrument....