The temperature modes’ dynamics in the system “primary clarifier - aerotank - secondary clarifier” of Rivne wwtp

Abstract

Wastewater treatment plants in Ukraine need modernization. Modernization should include the oxidation of organic substances and removal of nitrogen compounds. The temperature regime research was carried out at Rivne municipal wastewater treatment plant in Ukraine for reactors’ design of the oxidation of organic substances and nitrogen compounds. The biological wastewater treatment is performed in aeration tanks of 5 corridor construction. The design wastewater flow rate is 25,000 m3/day. The treated wastewater is discharged into River Ustya. The automated system of environment temperature measurement is developed and tested: clarified wastewater, mixture of wastewater and activated sludge, the activated sludge, treated waste water and the surrounding air. The unit of automatic fixing and data storage consists of the input module (MV110-224.8A), a data collecting module (MSD-200), memory card (MicroSD 8G) and power supply unit (BP30B-D3-24). Experimental data processing allows to choose the design temperature for the nitrification process in case of WWTP modernization and to avoid possible design errors. The temperature change is analyzed through all the profile of wastewater flow sheet of WWTP. Among the main causes of the sharp temperature change of wastewater (∆T> 2 ... 3oC) that comes to the system primary clarifier - aerotank - secondary clarifier of Rivne WWTP is a sharp increase or decrease of wastewater flow rate in the system. The research results allow considering the temperature regimes during the WWTP operation.

Authors and Affiliations

O. O. Hrytsyna

Keywords

Related Articles

Differential distribution of disperse masses in turnover cooling systems with vapor coolers

A technique for estimating the differential distribution of dispersed masses in circulating cooling systems with evaporative coolers is developed. The mass of the dispersed phase is formed when the circulating water is s...

A method of solving problems in statistical dynamics for the reliability assessment of complex technical systems with limited internal parameters of the system

This work was further develops the method of solving problems in statistical dynamics within the reliability assessment of complex technical systems. In applying the method of statistical tests (Monte Carlo) to assess th...

Full-scale test of conveyor gallery’s span for stiffness control

The results of full-scale test of conveyor gallery’s span for stiffness control in building conditions and numerical work are given. In 2016-2017 at grain terminal’s building near ‘Yujniy’ port assemblage of metalware wa...

The strength of cement stone on mechanically activated portland slag cement

Discusses the effect of mechanical activation of Portland cement with slag additive on the kinetics of strength development of cement stone. It is established that mechanical activation allows you to enter in Portland ce...

Evaluation of the pozzolanic activity of the ash of the TPP at application in energy effective concretes

The research of dependence of pozzolanic activity of wastes of power industry with different chemical and mineralogical composition received on different technologies of burning, selection and activating was carried out....

Download PDF file
  • EP ID EP327690
  • DOI -
  • Views 140
  • Downloads 0

How To Cite

O. O. Hrytsyna (2017). The temperature modes’ dynamics in the system “primary clarifier - aerotank - secondary clarifier” of Rivne wwtp. Вісник Одеської державної академії будівництва та архітектури, 1(69), 121-127. https://europub.co.uk/articles/-A-327690