Why Should We Have a Periodic Safety and Performance Program for Medical Devices
Journal Title: Journal of Biomedical Physics and Engineering - Year 2019, Vol 9, Issue 2
Abstract
Nowadays, more than 10,000 different types of medical devices can be found in hospitals.These devices used in medical centers and hospitals for monitoring and treatment of patients require periodic safety and performance checking in order to have confidence in their functioning and operation. Physicians need better accurate medical measurements in order to better diagnose diseases, monitor patients and deliver treatments, in this way failure to ensure appropriate measurements will certainly have diverse effects. Safety and performance testing of medical devices in the medical sector is a one of the key factor in improving public health. Acquiring results of some investigations indicate a need for new and severe regulations on periodic performance verifications and medical equipment quality control program especially in highrisks instruments. The metrological reliability of four high risk medical devices, Electrosurgical unit, Defibrillator, Syringe pump and Infant incubator in use some hospitals (privates and publics) in one of the province of Iran according to international and national standards was evaluated. Quantitative analysis of Some parameters that impact the safety and performance showed the amount of the obtained results in some equipment are in critical range and have higher values than standard limitations. General electrical safety evaluations for measuring the patient leakage currents and patient auxiliary currents carried out for all of groups,in some cases the amount of leakage currents were over the standard limitations. Acquiring results indicate a need for new and severe regulations on periodic performance verifications and medical equipment quality control program especially in high risk instruments. It is also necessary provide training courses for operating staff in the field of meterology in medicine and what’s the critical parameters and how they can get good accuracy results equipment.
Authors and Affiliations
A. Tavakoli Golpaygani
In-silico Evaluation of Rare Codons and their Positions in the Structure of ATP8b1 Gene
Background: Progressive familial intrahepatic cholestases (PFIC) are a spectrum of autosomal progressive liver diseases developing to end-stage liver disease. ATP8B1 deficiency caused by mutations in ATP8B1 gene encoding...
Monte Carlo Simulation of Siemens Primus plus Linac for 6 and 18 MV Photon Beams
Objective: The aim of the present study is to simulate 6 MV and 18 MV photon beam energies of a Siemens Primus Plus medical linear accelerator (Linac) and to verify the simulation by comparing the results with the measur...
Craniospinal Irradiation in Medulloblastoma using High Energy Medical Linear Accelerator: an Innovative Approach to Planning Technique
Background: Craniospinal irradiation (CSI) of medulloblastoma poses technological challenges due to the involvement of large treatment volume. Commonly, the whole treatment length is covered with two different isocentric...
Enhancement of Toxic Substances Clearance from Blood Equvalent Solution and Human Whole Blood through High Flux Dialyzer by 1 MHz Ultrasound
Background Hemodialysis is a process of removing waste and excess fluid from blood when kidneys cannot function efficiently. It often involves diverting blood to the filter of the dialysis machin to be cleared of toxic s...
The Influence of Brass Compensator Thickness and Field Size on Neutron Contamination Spectrum in 18MV Elekta SL 75/25 Medical Linear Accelerator with and without Flattening Filter: A Monte Carlo Study
Background: One of the most significant Intensity Modulated Radiation Therapy treatment benefits is a high target to normal tissue dose ratio. To improve this advantage, an additional accessory such as a compensator is u...