Analysis of the causes of failure in 5Cr-1Mo pipes mounted in a preheating furnace

Journal Title: Frattura ed Integrità Strutturale - Year 2012, Vol 6, Issue 20

Abstract

 The oxidation resistance of iron-based alloys depends on the formation of thin protective films consisting of reaction products between the alloys and the ambient atmosphere. The high corrosion resistance of Fe-Cr-Mo alloys has been attributed to the rapid formation of a uniform, highly protective passive film. The pipes hardness and resistance to various forms of corrosion are determined by the composition of the oxide layer that plays an important role in determining the lifetime of the pipes themselves. The thermal stability of the oxide layer is influenced by its composition and thickness as well as by the bond to the underlying metal. Determining factors for the high temperature corrosion are generally: temperature, metallurgy, TAN (chloridric and naphthenic acid), local flow conditions, sulphur compounds.

Authors and Affiliations

Adelina Borruto , Giovanni Narducci , Pietro Pietrosanti

Keywords

Related Articles

 Multiple and non-planar crack propagation analyses in thin structures using FCPAS

 In this study, multiple and non-planar crack propagation analyses are performed using Fracture and Crack Propagation Analysis System (FCPAS). In an effort to apply and validate FCPAS procedures for multiple a...

 The study of a defect evolution in iron under fatigue loading in gigacyclic fatigue regime

 The work is devoted to the study of the damage accumulation in iron under gigacyclic fatigue (VHCF) regime. The study of the mechanical properties of the samples with different state of life time existing was...

 Investigation of crack paths in natural fibre-reinforced composites

 Nowadays, fibre-reinforced composite materials are widely used in many fields, e.g. automotive and aerospace. Natural fibres such as flax and hemp provide good density specific mechanical properties. Additionally...

 Evaluation of near-threshold fatigue crack propagation in Ti-6Al-4V Alloy with harmonic structure created by Mechanical Milling and Spark Plasma Sintering

 Titanium alloy (Ti-6Al-4V) having a bimodal “harmonic structure”, which consists of coarsegrained structure surrounded by a network structure of fine grains, was fabricated by mechanical milling (MM) and spark pl...

 Fatigue methodology for life predictions for the wheel-rail contact area in large offshore turret bearings

  The present report presents a fatigue life prediction method for large roller bearings applied in the turret turn table for large loading buoy units. The contact points between wheel and rail in these bearings are...

Download PDF file
  • EP ID EP92571
  • DOI 10.3221/IGF-ESIS.20.03
  • Views 81
  • Downloads 0

How To Cite

Adelina Borruto, Giovanni Narducci, Pietro Pietrosanti (2012).  Analysis of the causes of failure in 5Cr-1Mo pipes mounted in a preheating furnace. Frattura ed Integrità Strutturale, 6(20), 22-31. https://europub.co.uk/articles/-A-92571